Home Contact Data protection Gen. Terms     Verifications Service Calibrations Contact Details
                   
 

Measures

 

Control Systems

 

Scales

Go to Humidity indicators.

Our Humidity indicators online.

Take a look at Humidity indicators.

 

Humidity indicators
On our website, you will find humidity indicators that can measure relative air humidity, or combined devices that can also
These Humidity indicators measure different ranges of humidity depending on the model measure temperature. These humidity indicators measure different ranges of humidity depending on the model. Relative air humidity is an important factor in most sectors, including industry, transport and gardening. They are versatile in that they can take measurements, store them to memory and transfer data to a computer for further detailed analysis. There is also the calibration standards for the device which makes it easy to ensure that measurements are extremely accurate. Many of our humidity indicators come with an ISO calibration certificate and some models are legally validated. They are very useful in evaluating damage in a warehouse. If you can't find the humidity indicators you are looking for, please contact us and we will help you find the best solution to suit your needs by calling our offices on: +44 (0)2380 987030 and our technical staff will advise you regarding our products.

Technical specifications for our Humidity indicators can be found at the following links:

- PCE-HT71 series Humidity indicators
  (internal sensor for temperature and humidity, memory for 32,000 values)

Humidity indicators with internal sensor for temperature and humidity, memory for 32,000 values.

- PCE-MSR145 series Humidity indicators
  (internal sensor for humidity, pressure, temperature, acceleration and position) 

Humidity indicators with internal sensor for humidity, pressure, temperature, acceleration and position.

- Log 100 / 110 series Humidity indicators
  (humidity indicators for temperature and humidity / with entrance for external sensor, 60.000 measurement values)

Humidity indicators for temperature and humidity / with entrance for external sensor, 60.000 measurement values.

- U12 series Humidity indicators
 
(temperature and humidity data loggers, EEPROM memory: 43000 values, USB)

Temperature and Humidity indicators with data loggers, EEPROM memory: 43000 values, USB.

- PCE-222 series Humidity indicators 
  (4 in 1 device with internal sensors for humidity, temperature, sound and lux)

4 in 1 Humidity indicators with internal sensors for humidity, temperature, sound and lux.

- PCE-EM882 series Humidity indicators 
  (4 in 1 with external sensors for humidity, temperature, sound and lux)

4 in 1 Humidity indicators with external sensors for humidity, temperature, sound and lux.

- PCE-EM 886 series Humidity indicators 
  (Sound, light, temperature, moisture, and external temperature, auto-ranging multimeter)

Humidity indicators with sound, light, temperature, moisture, and external temperature, auto-ranging multimeter.

- PCE-555 series Humidity indicators  Humidity indicators for measuring relative humidity, temperature and dew point.
  (for measuring relative humidity, temperature and dew point)

Humidity indicators for measuring relative humidity, temperature and dew point.

- PCE-310 series Humidity indicators
  (measures, temperature, humidity and dew point)

Humidity indicators to measure temperature, humidity and dew point

- PCE-320 series Humidity indicators
  (measures temperature, humidity and dew point, has connections for temperature sensors)

Humidity indicators to measure temperature, humidity and dew point, has connections for temperature sensors.

- PCE-HGP series Humidity indicators
  (combined detectors to measure relative and absolute humidity and temperature)

Humidity indicators to measure relative and absolute humidity and temperature.

- PCE-WM1 series Humidity indicators Humidity indicators for hygroscopic humidity in [g/m³] and [%], temperature, dew point ,external sensors.
  (hygroscopic humidity in [g/m³] and [%], temperature, dew point ,external sensors)

Humidity indicators for hygroscopic humidity in [g/m³] and [%], temperature, dew point ,external sensors.

- PCE-HT110 series Humidity indicators 
  (external display, data logger, sensor for temperature and humidity)

Humidity indicators with external display, data logger, sensor for temperature and humidity.

- PCE-THB 40 series Humidity indicators
  (humidity indicators to
ambient temperature, humidity and barometric pressure)

Humidity indicators to ambient temperature, humidity and barometric pressure, SD card

- EBI 2-TH-6.. series Humidity indicators
  (temperature and humidity data loggers / adjustable measurement / highly accurate)

Humidity indicators for temperature and humidity with data loggers / adjustable measurement / highly accurate

- PCE-313 A series Humidity indicators 
  (with memory, interface and software)

Humidity indicators with memory, interface and software.

- ThermoAir3 series Humidity indicators
  (humidity indicators to measure low air flow with a directional or multidirectional sensor)

Humidity indicators to measure low air flow with a directional or multidirectional sensor

- MiniAir20 / MiniWater20 series Humidity indicators
  (humidity indicators to measure very low flow speed / automatic probe detection)

Humidity indicators to measure very low flow speed / automatic probe detection

- PCE-SPS 1 series Humidity indicators
  (humidity indicators of movement to determine relative humidity, easy to use)

Humidity indicators of movement to determine relative humidity, easy to use

- PCE-APA 1 series Humidity indicators
  (vacuum humidity indicators, suitable for control and adjustments)

Vacuum Humidity indicators suitable for control and adjustments.

- PCE-G1 series Humidity indicators 
  (humidity and temperature, with a large display visible from up to 50m distance)

Humidity indicators  with a large display visible from up to 50m distance.

- PCE-G1A series Humidity indicators 
  (humidity indicators with two channels to humidity and temperature)

Humidity indicators with Two channels output humidity and temperature, 10 ... 95 % r.H. / 0 ... +60 °C.

- PCE-FWS 20 series Humidity indicators 
  (humidity indicators to measure temperature, humidity, pluviometry, wind speed, logger)

Humidity indicators to measure temperature, humidity, pluviometry, wind speed, logger, USB adapter, Software.

- RH5 series Humidity indicators 
  (humidity indicators for the moisture of stored paper)

Humidity indicators for the moisture of stored paper.

- AVM-4000 series Humidity indicators 
  (humidity indicators for temperature + humidity+ pressure..)

Humidity indicators for temperature + humidity+ pressure..

- WatchDog series Humidity indicators
  (cup humidity indicators to measure temperature, humidity, pluviometry, wind speed, logger)

Humidity indicators to measure temperature, humidity, pluviometry, wind speed, logger.

- PCE-THB 38 series Humidity indicators  
  (Thermometer, hygrometer and barometer in one handheld device)

Humidity indicators with Thermometer, hygrometer and barometer in one handheld device.

- FMU series Humidity indicators 
  (humidity indicators  for fixed installation of up to 99 humidity sensors)

Humidity indicators for fixed instalation of up to 99 humidity sensors.

- Humidity indicators  Humidity indicators and balances for measuring humidity content.
  (balance for measuring humidity content)

Humidity indicators - Balances: balance for measuring humidity content.

- Humidity indicators for stationary use
  (Humidity indicators for the connection to evaluation units, standard output signal)

Humidity indicators for the connection to evaluation units, standard output signal.

All humidity indicators come calibrated, but as their sensor's accuracy deteriorates with use, they should be recalibrated on a regular basis. A calibration can be done by the user of the device by using that optional calibration standards or the device can be sent to us and we will perform a recalibration that will meet ISO standards. (Calibration / recalibration of humidity indicators).

 Calibration standards for our Humidity indicators.                             Calibraton chamber of our Humidity indicators.                           ISO calibration certificate of our Humidity indicators.
     Recalibration standards                         Some devices use a                    ISO calibration certificate
    for humidity indicators                        calibration chamber                      for humidity indicators
 

Information about relative humidity: Relative humidity (r.h.) shows the relationship between absolute humidity (the amount really there) and the saturation state of water vapours. Relative air humidity is measured using humidity indicators, that show on their displays from 0% (absolutely dry air) up to 100% (air that is completely saturated, such as fog, clouds or steam bath). Some models of humidity indicators have an unlimited measurement range. The physical area is between 40 and 65% r.h. Given that hot air possesses the ability to absorb more water vapour than cold air, people feel that in winter, air is too dry and in summer it is too humid. If air heats up it increases the amount of water vapour to that of saturation. The consequence is that the % of relative humidity decreases while the real quantity of water remains constant. Something similar occurs when air is cooled, decreasing the quantity of water vapour. This increases the percentage value of relative humidity. Condensation forms when there is an excess of water in saturated conditions. Some of our humidity indicators offer the ability to not only measure relative humidity and temperature, but can also calculate dew point and dew point temperature. Dew point temperature is defined as the temperature at which the actual vapour content of air is the maximum (100% relative humidity). Dew point temperature is independant of the actual temperature. One possibility of dew point temperature is freezing metal until its surface forms condensation. The temperature of the metal will then be the dew point temperature. As we have mentioned, many of our humidity indicators show dew point on their display.

If you wish to view or print a selection of humidity indicators from our catalogue, click the PDF symbol.
Humidity indicators: Go to catalogue.

 

You are currently at: Home / measuring instruments and test equipment / Humidity indicators

If you have any questions, call our technicians on: +44 (0)2380 987030.

This page in German Humidity indicators in German. in Italian Humidity indicators in Italian. in Spanish Humidity indicators in Spanish. in Croatian Humidity indicators in Croatian. in French Humidity indicators in French.


Below you will find an overview of the different product groups of measuring instruments

Absolute Humidity Meters
Accelerometers
Alert Meters
Air velocity meters
Analyzers (Colour)
Analyzers (Combustion)

Analyzers (Gas)
Analyzers (Lan)
Analyzers (Noise)
Analyzers (Oxygen)
Analyzers (Ozono)

Anemometers
Barometers
Balances
Borescopes
Cable detectors (electrical)
Calibrators
Calipers
Cameras (Infrared Thermal Imaging)
Capacitance Meters
Coating Thickness Meters
Chlorine Meters
Clamp Meters
Climate Meters
Colour Meters

Conductivity Meters
Contact Thermometers
Current detectors

Data Loggers
Differential Pressure Meters
Digital Multimeters
Densimeters
Detectors (Humidity, Radiation, Voltage)
Dose Meters (Noise)
Durometers

Dust particle analyzers

Electric Tester
Endoscopes
Fiberscopes
Flow Meters Air
Flow Meters Gas
Force Gauges (digital)
Function generators
Frequency Meters
Gas Detector
Gaussmeters
Handheld Tachometers
Hardness Meters
Humidity Testers (Building material)
Hygrometers
Indicator Sound Level
Indicator (Humidity)
Instruments (Environmental)

Impedance bridges
Infrared Thermometers
Insulation Meters
Lan Network Testers
Laser Distance Meters
Laser level
Laser meters
Laser thermometers
LCR Meters
Length Meters
Light Meters
Lux Meters
Magnetometers
Manometers
Material Thickness Meters
Measurement Devices (Force)
Measuring Meters (Distance)
Measuring Wheels
Meters (Combustion, Distance, Earth,
Energy, Environmental, Gas, Gloss, Ground pH, Power Pressure, Radiation, Salt, Temperature)
Megohmmeters
Micrometers
Microscopes
Modular signal Converters
Moisture Indicator

Multimeters
Multi-Parameter Photometers
Noise Meters
Odometers
Ohm Meters
Oscilloscopes
Oxygen Meters
Ozone Meters
 Noise Meters
 Occupational hazards 
 O
dometers
 Ohm Meters
 Oscilloscopes
 Oxygen Meters
Paper Moisture Meters
Penetrometers

Phase rotation meters
Photovoltanic meters
Pitot tube air flow meters
Pocket pH-meters
Power Analyzers
Pressure Gauges
Pyrometers
Quality Meters (Air)
Radiation Counters
Radioactivity meters
Reader (Temperature)
Recorders Data
Redox Meters
Refractometers
Relative Humidity Meters
Resistance Testers
Rotation meters
Roughness tester
Rotation meters
Roughness tester
Scales
Sensor (Temperature)
Signal converters
Signal Level Analyzers
Single-parameter Photometers
Sound Level Meters
Systems for Environmental
Stethoscopes (electronic)
Stroboscopes
Surface Thickness Meters

Tachometers
Telescope Meters
Thermo-anemometers
Thermo-Hygrometers
Temperature Probes
Testers Air
Testers Conductivity
Testers Earth
Testers Insulation
Testers Noise
Testers pH
Testers paper
Testers Sound
Testers Temperature
Thermal stress
Thermal Imaging Cameras
Thermometers
Thermocouples
Thickness Meters
Torque meters

Ultrasonic Flow Meters

VDE tester
Vibration Meters
Video endoscopes
Voltage meters
Weather Stations
Wood (humidity)