Measures

Distribución de todo tipo de básculas en toda Europa: de PCE Group
UK office: +44 (0) 191 3773398 Fax: +44 (0) 191 3773357

Home
Business Terms
Faq's
Contact
 


Business
Terms


Contact

Calibra-
tion
service


Refe-
rences


Measuring
instruments


Scales and
Balances


Laboratory scale topseller

laboratory scale: PCE-999
Noise meters

laboratory scale
Radiation
detectors


laboratory scale: PCE-LD 1
Gas
detectors


laboratory scale: PCE-OC 1
Oscilloscopes

laboratory scale:: PCE-T395
Thermometers

laboratory scale:PCE-313A
Humidity
indicators


laboratory scale:PCE-DC 3.
Clamp
meters

laboratory scale:PCE-228
pH-Meters

laboratory scale:PCE-S 41
Stethoscopes

laboratory scale:PCE-DM 12
Isolation
meter


laboratory scale:PCE-830
Power and
harmonics analyser


laboratory scale:PCE-AM 81
Earth meters

laboratory scale:PCE-AM 81
Anemometers

laboratory scale:PCE-TC 3
Thermal
cameras


laboratory scale:PCE-889
Infrared
thermometers


laboratory scale:PCE-PH 22
Conductivity
meters


laboratory scale:PCE-VE 110
Videoscopes

laboratory scale:PCE-CT 28
Coating
thickness
meters


laboratory scale:PCE-G 28
Radiation
analysers


laboratory scale:PCE-G 28
Weather
stations


laboratory scale:PCE-G 28
Microscopes
USB


laboratory scale:PCE-G 28
Microscopes
 


Bordelaboratory scale:PCE-BS
Tabletop
scales

laboratory scale:PCE-CS HD
Crane
scales



Laboratory
Scales

laboratory scale:PCE-MB
Humidity content
Scales


laboratory scale:PCE-HS50
Hanging
Scales


laboratory scale:PCE-DS600
Kitchen
scales


laboratory scale:PCE-JS 300
Pocket
scales


laboratory scale:PCE-JS 300
Pallet truck
scales

laboratory scale:PCE-JS 300
Floor scales

PCE-123 calibrator
indicates the nominal value for simulations and measurement of input
electrical signals such as frequency and temperature

The PCE-123 process calibrator / nominal value indicator is a device that does need a mains connector and that is used to simulate regulation signals or units en the MSR technique with which it can test and calibrate almost any unit parameter and measuring instrument. The nominal value indicator provides an electrical output signal (mA, mV, V and frequency in Hz as well as temperature in °C or °F). The calibrator other automatic graduated functions, and selection of output signal jumps by percentage (0 to 100%) via the up/down keys and direct display of the output value. The device is easy to use and is operated via the keypad. THis device is attractive due to its high level of accuracy and its universal range of applications which no electrician or MSR department should go without, as well as within the industrial sector.

This device we have on offer is a high quality alternative to those which are normally found on the market.

 - 4 to 20mA (1kΩ, 24V power)
 - 0 to 100.00 mV / 0 to 1,0000V / 0 to 12,000V
 - type-K, J, E, T temperature sensors (°C or °F)
 - Frequency range 1 to 62,500Hz
 - Accuracy of 0.025%
 - Operated via keypad
 - Graduated automatic functions
 - Selectable between 0 to 20mA/ 0 to 24mA
 - Input 0 to 100% (mA, mV, V )
 - Alarm beep 'open' (mA) or 'short circuit' (mV, V

 View or print the user's manual
  PCE-123 calibrator: View or print the user's manual.

PCE-123 process calibrator
PCE-123 process calibrator
 

Areas of application

PCE-123 calibrator with an SLT digital indicator

- The first image shown is the PCE-123 calibrating our SLT acoustic installation. The measurement range is from 30 to 130dB (A) for an input signal of 4 to 20mA.
  The calibrator emits, in this instance, as signal adjusted to 50% = 12mA (range 4 - 20mA) that corresponds to an indicator of 50% =  65 (64.9) dB(A) of the unit indicated. The accuracy of the SLT can be seen.


- The second image shows an example of us testing the display of our high precision PCE-T395 thermometer. The calibrator is adjusted to type-k and with a thermal tension /temperature of 200°C. The PCE-T395 shows the value accurately and with that the device is ready to be sent to the client.
- If you wish to learn more about our PCE-T395 thermometer with data logger function, software and data cable, click here.

PCE-123 calibrator: calibrating a PCE-T395.

PCE-123 calibrator: calibrating a PCE-DM22 multimeter

- In the last example we test the accuracy of a frequency measurement with our PCE-DM22 multi-meter with integrated data logger.
  The process calibrator is adjusted to an input signal of 20kHz and as it was shown on our multimeter.
- If you do not have a high spec multi-meter like this in your shop or in your production process, click here.

The above examples show a wide range of uses, in profession practice, for the PCE-123 process calibrator.
The PCE-123 calibrator is highly useful in laboratories, in MSR workshops or to test measurement instruments in research and development.

Technical specifications

mA DC current
(maximum load at 1kΩ, powered by 24V)

Range 4 to 20mA / 0 to 20mA / 0 to 24mA
Resolution 1µA
Accuracy ±0.025% ±3µA
Alert beeps when there is a short circuit or ouput current >1mA .

mV current, V DC
(power 1mA)

Ranges 0 to 100.00 mV
0 to 10.000 V
0 to 1.0000 V
Resolution 10 µV
1 mV
1.0000 V
Accuracy ± 0.05% ±30 µV
± 0.05% ±3 mV
± 0.05% ±300 µV
Alert beeps when there is a short circuit or ouput current >10mV.
Temperature sensor type-K, J, E, T 
(1 kΩ min.)
Ranges K: -200 to 0°C and 0 to 1370°C 
J:  -100 to 0°C and 0 to 760°C
E: -10to 0°C and 0 to 700°C
T:  -200 to 0°C and T: 0 to 400°C
Resolution 1°C (across entire range)
Accuracy K: ±1.1°C and ±0.8°C
J:  ±0.9°C and ±0.7°C
E: ±0.9°C and ±0.7°C
T:  ±1.0°C and ±0.8°C

Frequency

Range 1 to 125Hz and 126 to 62.5kHz
Resolution 1 to 125Hz / 1Hz 126 to 62.5kHz / 604 readings 
Accuracy ±0.04Hz
Selection 604 frequencies

General characteristics

Display 5 position LCD
Operating conditions 0 to 50°C; <85% r.h.
Storage conditions -20 to 60°C; <85% r.h.
Power 1 9V battery or 6 x 1.5V batteries
Consumption 60mA to 180mA (depending on output)
Battery indicator 5.5V for 150mA
Dimensions 88 x 168 x 26mm
Weight 330g

Contents
PCE-123 process calibrator, carrying case, type-k adaptor, 6 batteries, test cables with alligator clips and user's manual

Optional accessories
- ISO calibration certificate for companies that wish to incorporate the device into their set of internal quality control tools or for annual recalibrations.
  The ISO certification contains a laboratory calibration with a certificate containing all the measurement data.


ISO calibration certificate for the PCE-123 calibrator.

technical specifications for PCE-123 calibrator. return to homepage

Here you will find an overview of all the measuring instruments available at PCE Group.

Contact:
Companies House England
Tursdale Business Park
Co. Durham - DH6 5PG
United Kingdom
Phone. +44 ( 0 ) 191 377 3398

Fax +44 ( 0 ) 191 377 3357

This page in German the PCE-123 process calibrator in German in Italian the PCE-123 process calibrator in Italian in Spanish the PCE-123 process calibrator in Spanish in Croatian the PCE-123 process calibrator in Croatian in French the PCE-123 process calibrator in French


Below you will find an overview of the different product groups of measuring instruments

 Absolute Humidity Meters
 Accelerometers
 Alert Meters
 Air velocity meters
 Analyzers (Colour)
 Analyzers (Gas)
 Analyzers (Lan)
 Analyzers (Noise)
 Analyzers (Oxygen)
 Analyzers (Ozono)
 Anemometers
 Barometers
 Borescopes

Cable detectors (electrical)
Calibrators
Cameras (Infrared Thermal Imaging)
Capacitance Meters
Coating Thickness Meters
Chlorine Meters
Clamp Meters
Climate Meters
Colour Meters
Conductivity Meters
Contact Thermometers
Current detectors

Data Loggers
Differential Pressure Meters
Digital Multimeters
Densimeters
Detectors (Humidity, Radiation, Voltage)
Dose Meters (Noise)

 Earth meters
 Endoscopes
 Environmental Meters

 Fiberscopes
 Flow Meters Air
 Flow Meters Gas
 Force Gauges (digital)
 Frequency Meters

 Gas detectors
 Geiger Counter

 Handheld Tachometers
 Hardness Meters
 Humidity Testers
 (Building material)
 
Hygrometers

Indicator Sound Level
Indicators (Humidity)
Instruments (Environmental)

Impedance bridges
Infrared Thermometers
Isolation Meters

Lan Network Testers
Laser Distance Meters
Laser level
Laser meters
Laser thermometers
LCR Meters
Length Meters
Light Meters
Lux Meters

 Magnetometers
 Manometers
 Material Thickness meters

 Measurement Devices
 (Force)
 Measuring Meters
 (Distance)
 Measuring Wheels
 Meters (Distance)
 Meters (Ozone) 
 Meters (Gas) 
 Meters (Gloss)
 Meters (pH)
 Meters (Power)
 Meters (Pressure)  
 Meters (Radiation)
 Meters (Temperature)  
 Micrometers
 Microscopes
 Modular signal 
 Converters
 Moisture Indicator
 Multimeters
 Multi-Parameter    
 photometers

Noise Meters

 Odometers
 Ohm Meters
 Oscilloscopes
 Oxygen Meters
 Paper Moisture Meters
 Penetrometers
 Pitot tube air flow
 meters
 Pocket pH-meters
 Power Analyzers
 Pressure Gauges
 Pyrometers
 Quality Meters (Air)
 Radiation Counters
 Radioactivity meters
 Reader (Temperature)

 Recoders Data
 Redox Meters
 Refractometers

 Relat. Humidity meters
 Rotation meters
 Roughness tester
 Salt Meters
 Sensor (Temperature)
 Signal Level Analyzers
 Single-parameter  
 Photometers
 Sound Level Meters
 Systems for 
 Environmental
 Stethoscopes 
 (electronic)
 Stroboscopes
 Surface Thickness 
 meters

Tachometers
Telescope Meters
Thermo-anemometers
Thermo-Hygrometers
Temperature Probes
Testers (Air)
Tester (Conductivity) Tester (Earth)
Tester (Electric)
Tester (Insulation)  Tester (Noise)
Tester (pH)
Tester Resistance Tester (Sound)
Tester (Temperature)
Thermal stress
Thermal Imaging Cameras
Thermometers
Thermocouples
Thickness Meters
Turdibity Meters

Ultrasonic Flow Meters

VDE tester
Vibration Meters
Video endoscopes
Voltage meters