W-20-TRMS Digital Voltmeter digital voltmeter with RS-232 interface, software. The real effective value can be measured
|
|
The W-20-TRMS digital voltmeter has an indicator with diverse symbols to show the different functions, as well as two warning symbols: one to show when the fuse is damaged and another one when the condenser is downloaded. In the digital voltmeter, cracks are indicated according to the selected measurement range. An alarm for errors and an acoustic signal are additional. This voltmeter will also determine capacitance, frequency and temperature. Our company also includes the software and the data cable in the delivery. There is another model of a voltmeter with multiple functions, graphics, interface and software (multimeter, oscilloscope, logic analyser ...) which can be seen here. Another similar voltmeter which is easier to use is the PCE-DM 22 Voltmeter. At this link you will find an overview of all the different voltmeters available from PCE-Group:I
|
- 3 ¾ positions and high contrast LCD display (71 x 49 mm); maxi. 4000
- Water / dust resistant housing
- Measurement of the real effective value
- Overload protection in the whole range
- RS-232 C interface and software for Windows 95 / 98 / 2000 / NT / ME / XP
- Data Hold and relative value functions
- Acoustic alarm
- Diode test function
- Automatic / hand selection
- Measurement in % of operative cycles
- Security: IEC-1010-1; CAT II 1000 V / CAT 600 V
- Delivery contents: RS-232 interface cable, software, hitching unit, testing cable, K thermal sensor, replacement fuse, battery and user's manual.
|
 W-20-TRMS digital voltmeter with RS-232 interface and software for data to be transferred to a computer.
|
| Technical specifications |
| DC Voltage |
400 mV 4 V 40 V 400 V 1000 V |
± 0.3 % + 5 dgt. ± 0.1 % + 5 dgt. ± 0.1 % + 5 dgt. ± 0.1 % + 5 dgt. ± 0.5 % + 5 dgt. |
100 μV 1 mV 10 mV 100 mV 1 V |
|
AC Voltage
|
400 mV 4 V 40 V 400 V 700 V |
± 1.5 % + 5 dgt. ± 1.0 % + 5 dgt. ± 1.0 % + 5 dgt. ± 1.0 % + 5 dgt. ± 1.0 % + 5 dgt. |
100 μV 1 mV 10 mV 100 mV 1 V |
|
DC Current
|
400 μA 4 mA 40 mA 400 mA 20 A |
± 1.2 % + 10 dgt. ± 1.2 % + 10 dgt. ± 1.5 % + 10 dgt. ± 1.5 % + 10 dgt. ± 2.0 % + 10 dgt. |
0.1 μA 1.0 μA 10 μA 100 μA 10 mA |
|
AC Current
|
400 μA 4 mA 40 mA 400 mA 20 A |
± 1.5 % + 10 dgt. ± 1.5 % + 10 dgt. ± 1.5 % + 10 dgt. ± 1.5 % + 10 dgt. ± 2.0 % + 10 dgt. |
- 0.1 μA - 1 μA - 10 μA - 100 μA - 1 mA |
|
Resistance
|
0 Ω / 4 / 40 / 400 kΩ / 4 / 40 MΩ ± 1 % + 5 dgt. - 100 mΩ |
| Capacitance |
4 / 400 nF / 4 / 40 / 100 μF ± 3 % + 10 dgt. - 10 pF |
| Frequency |
10 Hz ... 10 MHz ± 0.1 % + 2 dgt. - 10 mHz |
|
Temperature
|
-20 °C ... +1370 °C ± 3 % + 5 dgt. - 0,1 °C |
| Over voltage |
CAT II 1000 V / CAT III 600 V |
| Power |
de 9 V battery |
| Dimensions |
88 x 178 x 33 mm |
| Weight |
315 g |
| Uses of the W-20-TRMS digital voltmeter |
|
With this instrument printed circuit assembly can be checked by testing the different components and verifying conduction. The voltmeter can be also used in the electrical sector due to the fact that it is possible to select a higher voltage range.
|

|
|
Delivery contents 1 W-20-TRMS digital voltmeter, a RS-232 interface cable, software, 1 hitching device, 1 testing cable, a K thermal sensor, 1 replacement fuse, 1 battery, and user's manual
|
| Optional devices
- SO calibration certificate For companies that wish to include this device in their set of internal testing tools or for annual recalibrations. The ISO certificate includes a laboratory calibration and a control document with all the measurement values. ISO calibration certificate can be carried out in voltage (AC / DC) or in current.
|
 |
|
- Amp clamp adaptor Adaptor for indirect measurement of current up to 1000A without interrupting the cable. - Range: 200 / 1000A DC / AC - Accuracy: ±1.5 / 2% - A DC zero reset - Dimensions: 190 x 64 x 33mm - Maximum diameter of cable: 33.5mm
|
 |
Revolution adaptor Adaptor with revolutions sensor and 1m cable. For optical measurement of revolution between 100 and 20,000 RPM in two ranges. - 0.1mV DC / 1 RPM (range 1) - 0.1mV DC / 10 RPM (range 2) - Dimensions: 190 x 73 x 37mm |
 |
- Pressure adaptor Adaptor with pressure sensor and 1m cable. For absolute measurement of pressure between 3.5 and 3500kPa. - Accuracy: ±1% (up to 1700 kPa); ±2% (up to 2400 kPa) and ±5% (up to 3500 kPa) - Resolution: 0.1/ 1 kPa - Dimensions: 100 x 50 x 25mm; 1/4" sensor |
 |
|
- Humidity adaptor Adaptor with humidity sensor in a handle and with 1m cable. - Range: 10 to 95% r.h. - Accuracy: ±3% r.h. - Resolution: 0.1% r.h. - Dimensions: 100 x 50 x 25mm
|
 |
|
- Light adaptor Adaptor with light sensor and 1m cable. - Three rages: 0 to 2000 / 0 to 20,000 and 0 to 50,000 lux - Accuracy: ±5% - Resolution: 1, 10, 100 lux - Dimensions: 100 x 50 x 25mm
|
 |
- Air velocity adaptor Adaptor with an air velocity sensor and 1m cable. - Range: 0.2 to 30 m/s; - Accuracy: ±2% - Resolution: 0.1 (m/s; km/h; knots) - Dimensions: 100 x 50 x 25mm |
 |
- Sound adaptor Adaptor with sound sensor and 1m cable. A-weighting; can be externally calibrated (PCE-SC 41 calibrator) - Ranges: 30 to 130dB (in three ranges) - Accuracy: ±1.5dB (IEC 651 clase II) - Dimensions: 107 x 53 x 29mm |
 |
- EMF adaptor Adaptor with EMF sensor and 1m cable. Range: 0 to 20 microTesla / 200 milliGauss Accuracy: ±4% Resolution: 0.1 µTesla / 1 milliGauss Bandwidth: 30 to 300 Hz Dimensions: 100 x 50 x 25mm |
 |
|

|
 |
|
Here you will find an overview of all the measuring instruments available at PCE Instruments.
|
|
Contact: PCE Instruments UK Limited Units 12/13 Southpoint Business Park Ensign Way, Southampton United Kingdom, SO31 4RF Phone. +44 ( 0 ) 2380 98703 0 Fax +44 ( 0 ) 2380 98703 0
|
|
This page in German in Italian in Spanish in Croatian in French .
|