PCE-UT 803 tabletop
multimeter
real effective value
multimeter with multiple measurement functions, RS-232
and USB interface, software and powered via the
mains or by batteries. |
|
PCE-UT tabletop multimeter can be used both as a
mobile or fixed device. This tabletop multimeter can
be powered via the mains or by batteries. Thanks to
its wide measurement ranges, this multimeter can be
used to cover all your needs. Along with determining
DCV, ACV, DCA, ACA and resistance accurately, this
multimeter will also determine capacitance,
frequency, revolutions and temperature, as well as
doing continuity checks and diode tests. Data can
also e transferred to a computer with the help of
the software included in the delivery (USB and RS-232
data cable is also included). The integrated data
logger function allows the user to take measurements
over a duration of time in machines and electrical
installations. This tabletop multimeter comes
calibrated from the factory and an ISO calibration
certificate can be ordered with the device or as
annual recalibrations.
There is another model of multimeter with multiple
functions, graphics, RS-232 interface and software (osciloscope,
multimeter, logical analyzer) which can be seen
here. If you also
require an instrument to measure capacitance,
frequency and temperature we recommend the
W-20-TRMS.
Furthermore, at this
link
you will find and overview of the multimetres
available form PCE-Group. |
|

PCE-UT
803 tabletop multimeter |
|
Integrated compartment
accessories for the PCE-UT 803 multimeter |
Additional components for
the
PCE-UT 803 multimeter. |
-
Highly accurate
-
Automatic / manual range
selection
-
DCV, ACV, DCA, ACA,
resistance, capacitance, frequency, temperature,
transistor tests.
-
Continuity check and
diode test.
-
Measurement of the real
effective value.
-
Mín./máx./HOLD functions
-
Auto shut-off function (it
can be deactivated)
-
Battery indicator.
-
Big back-light LCD
display.
|
-
USB y RS-232 interface.
-
Software and data cable
are included in the delivery.
-
Powered via the mains or
by batteries.
-
Frequency measurement up
to 60 MHz.
-
An ISO Calibration
Certificate can be additionally issued.
-
Protected according to IEC .
1010; CAT I 1000 V / II 600 V
View / Print PCE UT 803
tabletop multimeter user's manual
 |
|

PCE-UT 803 multimeter: Backside with both
interfaces. |
|
Technical specifications |
|
Measurement ranges |
DCV:
600 mV/ 6/ 60/ 600/ 1000 V
ACV: 600 mV/ 6/
60/ 600/ 750 V
DCA: 600/ 6000 µA; 60/ 600 mA; 10 A
ACA: 600/ 6000 µA; 60/ 600 mA; 10 A
OHM: 600 Ω;
6/ 60/ 600 kΩ; 6/60 MΩ
Cap.: 6/ 60/ 600 nF;
6/ 60/ 600 µF; 6 mF
Frec.: 6/ 60/ 600 kHz; 6/ 60 MHz
Temp.: -40 °C ... +1000 °C |
|
Resolution |
DCV:
0,1 mV; 0,001/ 0,01/ 0,1/ 1 V
ACV: 0,1 mV;
0,001/ 0,01/ 0,1/ 1 V
DCA: 0,1/ 1 µA;
0,01/ 0,1 mA; 0,01 A
ACA: 0,1/ 1 µA;
0,01/ 0,1 mA; 0,01 A
OHM: 0,1/ 1/ 10/ 100 Ω;
1/ 10 k Ω
Cap.: 1/ 10/
100 pF; 1/ 10/ 100 nF; 1 µF
Frec.: 1/ 10/
100 Hz; 1/ 10 kHz
Temp.: 1 °C |
|
Accuracy |
DCV:
± 0,3 % del indic. + 2 dgt (hasta 600 V);
± 0,5% + 3 dgt (por encima)
ACV: ± 0,6 %
del indic.
+ 5 dgt (hasta 600 V);
± 1,2 % + 3 dgt (por
encima)
DCA: ± 0,5 %
del indic. + 3 dgt (bis 60 mA);
± 0,8 % + 3 dgt (hata 600 mA)
± 1,2 % + 3
dgt (por
encima)
ACA: ± 1,0 % del
indic.
+ 5 dgt (hasta 600 mA)
±
2
% + 6 dgt (por
encima)
OHM: ± 0,5 % del indic.+ 2 dgt (hasta 600 kΩ);
± 0,8 % + 2 dgt (a 6 MΩ)
±1,2 % + 3
dgt (por
encima)
Cap.: ± 2 % del indic.+ 5 dgt (hasta 60µF)
±3 % del indic.+ 4 dgt (hasta
60µF)
±5 % del
indic.+ 4 dgt (a 6 mF)
Frec.: ± 0,1 %
del indic.+ 3 dgt
Temp.: ± 1,0 % del
indic. + 3 dgt |
|
Measurement quota |
2-3 / s |
|
Continuity check acoustic
signal |
below 30 Ω |
|
Diode test |
up to 2,7 V/1 mA |
|
Puerto |
USB y RS-232 |
|
Software data cable |
Both are included in the
delivery. They are able for all windows systems. |
|
Display max. resolution |
back-light LCD display with
a maximum value of 5999 |
|
Power |
230 VAC and / or 6 x 1,5 V
batteries |
|
Auto shut-off |
after 10 minutes without
working (it can be deactivated) |
|
Dimensions |
2408 x 105 x 310 mm |
|
Weight |
2000 g |
|
Enviromental conditions |
máx. 70% H.r. / 0 ... +50 şC |
|
Protection / Standard |
IEC 1010-1, CAT I 1000 V/ II
600 V |
|
Use of the multimeter |
|
 |
|
Tabletop multimeter
software |
|
Graphic representation of some measurements took with
the PCE-UT 803 multimeter. |
|
Contents
1 x PCE-UT 803 tabletop multimeter, 1 x test cable
set, 2 x big alligator clips, 2 x small alligator
clips, temperature sensor (K type), 1 x adapter, 1x
battery, 1x mains adaptor, 1x USB cable, 1 x RS-232
cable, 1x software and user's manual |
|
Additional components
- ISO Calibration Certificate
For companies that wish to
include this device in their
set of internal testing
tools or for annual
recalibrations. The ISO
certificate includes a
laboratory calibration and a
control document with all
the measurement values. ISO
calibration certificate can
be performed with current
(AC / DC) or voltage (AC /
DC). |
 |
-
Amp clamp adaptor
Adaptor for indirect
measurement of current up to
1000A without interrupting the
cable.
- Range: 200 / 1000A DC / AC
- Accuracy: ±1.5 / 2%
- A DC zero reset
Dimensions: 190 x 64 x 33mm
Maximum diameter of cable:
33.5mm |
 |
-
Revolution adaptor
Adaptor with revolutions
sensor and 1m cable.
For optical measurement
of revolution between 100
and 20,000 RPM in two ranges.
- 0.1mV DC / 1 RPM (range
1)
- 0.1mV DC / 10 RPM (range
2)
Dimensions: 190 x 73 x
37mm |
 |
-
Pressure adaptor
Adaptor with pressure
sensor and 1m cable.
For absolute mesaurement
of pressure between 3.5 and
3500kPa.
- Accuracy: ±1% (up to
1700 kPa); ±2% (up to 2400
kPa) and ±5% (up to 3500 kPa)
- Resolution: 0.1/ 1 kPa
Dimensions: 100 x 50 x
25mm; 1/4" sensor |
 |
-
Humidity adaptor
Adaptor with humidity
sensor in a handle and with
1m cable.
- Range: 10 to 95% r.h.
- Accuracy: ±3% r.h.
- Resolution: 0.1% r.h.
Dimensions: 100 x 50 x
25mm |
 |
-
Light adaptor
Adaptor with light sensor
and 1m cable.
- Three rages: 0 to 2000
/ 0 to 20,000 and 0 to
50,000 lux
- Accuracy: ±5%
- Resolution: 1, 10, 100
lux
Dimensions: 100 x 50 x
25mmA |
 |
Air
velocity adaptor
Adaptor with an air
velocity sensor and 1m
cable.
- Range: 0.2 to 30 m/s;
- Accuracy: ±2%
- Resolutin: 0.1 (m/s; km/h;
knots)
Dimensions: 100 x 50 x
25mm |
 |
-
Sound adaptor
Adaptor with sound sensor
and 1m cable.
A-weighting; can be
externally calibrated
(PCE-SC 41 calibrator)
- Ranges: 30 to 130dB (in
three ranges)
- Accuracy: ±1.5dB (IEC
651 class II)
Dimensions: 107 x 53 x
29mm |
 |
-
EMF adaptor
Adaptor with EMF sensor
and 1m cable.
Range: 0 to 20 microTesla
/ 200 milliGauss
Accuracy: ±4%
Resolution: 0.1 µTesla /
1 milliGauss
Bandwidth: 30 to 300 Hz
Dimensions: 100 x 50 x
25mm |
 |
 |
 |
| Here you will find an overview of all the measuring instruments available at PCE Group. |
Contact:
Companies House England
Tursdale Business Park
Co. Durham - DH6 5PG
United Kingdom
Phone. +44 ( 0 ) 191 377 3398
Fax +44 ( 0 ) 191 377 3357 |
|
This page in German
in Italian
in Spanish
in Croatian
in French
. |