 The PCE-PCM2 clamp meter is designed to measure both alternating and direct current up to 1500 A. The PCE-PCM2 clamp meter can also detect power by measuring voltage and current. The PCE-PCM2 clamp meter is also used to measure diode resistance, capacity, continuity and voltage. The PCE-PCM2 clamp meter additionally determines mains frequency. Through an internal sensor, the PCE-PCM2 clamp meter can detect voltage-free lines. The PCE-PCM2 clamp meter can perform measurements in cables and lines with a maximum diameter of 52 mm. The large backlit LED display ensures easy reading of measured values. The PCE-PCM2 clamp meter has a robust and rubberized enclosure which allows to use it even in adverse conditions. Here you will find an overview of all the clamp meters available at PCE Instruments.  | 
||
| 
 View or print user manual of the PCE-PCM2 Clamp Meter    | 
||
| 
 - Measures current up to 1500 A - Measures AC/DC power - Measures voltage up to 1000 V  | 
 - Temperature measurement through a  - Displays digital bar-graph - Search of current lines  | 
|
| 
 Technical specifications:  | 
||
| DC A current | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 400 A | 0.01 A | ±(2 % + 30 digits) | 
| 1000 A | 0.1 A | ±(2.5 % + 30 digits) | 
| AC A current | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 400 A | 0.01 A | ±(2.5 % + 30 digits) | 
| 1000 A | 0.1 A | ±(2.8 % + 30 digits) | 
| 
 Note: The mentioned accuracy refers to AC A measurements within a range between 5 % and 100 % of the measurement range.  | 
||
| DC A voltage | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 400 mV | 0.01 mA | ±(0.1 % + 9 digits) | 
| 4 V | 0.0001 V | ±(0.1 % + 4 digits) | 
| 40 V | 0.001 V | ±(0.1 % + 4 digits) | 
| 400 V | 0.01 V | ±(0.1 % + 4 digits) | 
| 1000 V | 0.1 V | ±(0.5 % + 4 digits) | 
| Voltage measurement (AC V, 50 ... 100 Hz) | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 400 mV | 0.01 mV |  ± (0.8 % + 9 digits at  50/60 Hz)  | 
| 4 V | 0.0001 V | ± (1 % + 30 digits) | 
| 40 V | 0.001 V | ± (1 % + 30 digits) | 
| 400 V | 0.01 V | ± (1 % + 30 digits) | 
| 750 V | 0.1 V | ± (1 % + 30 digits) | 
| Note: Mentioned accuracy refers to AC A measurements within a range between 5 % and 100 % of the measurement range. | ||
| Power DC kW measurement (0 to 600 V, 0 to 1500 A) | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 900 kW | 0.1 | ± (2.8 % + 10 digits) | 
| Power measurement (0 to 600 V, 0 to 1500 A) | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 900 kW | 0.1 | ± (3 % + 10 digits) | 
| Note: The mentioned accuracy refers to AC A measurements within a range between 5 % and 100 % of the measurement range. | ||
| Resistance measurement | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 400 Ω | 0.01 | ± (0.5 % + 9 digits) | 
| 4 kΩ | 0.0001 | ± (1 % + 4 digits) | 
| 40 kΩ | 0.001 | ± (1 % + 4 digits) | 
| 400 kΩ | 0.01 | ± (1 % + 4 digits) | 
| 4 MΩ | 0.0001 | ± (2 % + 10 digits) | 
| 40 MΩ | 0.001 | ± (3 % + 10 digits) | 
| Capacity | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 400 nF | 0.01 | ± (3.5 % + 40 digits) | 
| 4000 nF | 0.1 | ± (3.5 % + 10 digits) | 
| 40 µF | 0.001 | ± (3.5 % + 10 digits) | 
| 400 µF | 0.01 | ± (3.5 % + 10 digits) | 
| 4 mF | 0.0001 | ± (5 % + 10 digits) | 
| 20 mF | 0.001 | ± (5 % + 10 digits) | 
| 420 mF | 0.001 | non-specified | 
| Frequency measurement | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 40 Hz | 0.001 | ± (0.3 % + 2 digits) | 
| 400 Hz | 0.01 | |
| 4 kHz | 0.0001 | |
| 40 kHz | 0.001 | |
| 400 kHz | 0.01 | |
| 4 MHz | 0.0001 | |
| 40 MHz | 0.001 | |
| Working cycle | ||
| 
 Measurement Range  | 
 Resolution  | 
Accuracy | 
| 10 ... 95 % | 0.1 |  ± (1 % + 2 digits) (of the measurement value)  | 
| Temperature | Resolution | Accuracy | 
| -100 ... 1000 ºC | 0.1 |  ± (1% ... +2.5 ºC) (of the measurement value)  | 
| General technical specification: | ||
| Diameter of the conductor | 
 max. 52 mm  | 
|
| Display | two lines 40.000/4.00 | |
| Input impedance | 10 MΩ | |
| Bandwidth AC (AC A/AC V) | 50 ... 400 Hz | |
| AC Measurement | True effective value | |
| Operating conditions | 
  5 ... 40 ºC  | 
|
| Storage conditions |  -20 ... 60 ºC max. 80 % <80 % H.r.  | 
|
| Power supply | 9 V battery | |
| Auto shut-off | 
 after approx. 30 minutes  | 
|
| Dimensions | 
 294 x 105 x 47 mm  | 
|
| Weight | 536 g | |
| Standards | IEC 1010-1, EN 61010-1, CAT III | |
| 
    | 
||
| 
    | 