 ICM5 signal converter: protocol converter   (protocol converter from RS 232 to RS 485 or RS 422)  
 | 
| 
 The ICM5 signal / protocol converter can connect devices with RS 232 protocols to other devices with RS 485 or RS 422 protocols if there is a concordance between data formats. The ICM5 signal converter has galvanic insulation to avoid damages in the connected instruments produced by peak voltages, etc.... The ICM5 signal / protocol converter has three LED on the front panel to indicate if there is enough power (the green LED is lighted) or if the device is sending (the red LED is flashing) or receiving signals through the RS 232 protocol. The ICM5 signal/protocol converter is powered by 9 - 26 VDC. The ICM5 signal/protocol converter is simply slid on a C-rail or mounting rail.     The ICM5 signal/protocol converter is delivered with a default setting which means that the desired conversion is normally performed in the 99% of the cases without adapting the instrument but simply by holding the device and start working.  
 | 
| 
  - Converts RS 232 to RS 485 / RS 422   - Galvanic insulation up to 1000 VDC   - 9-terminal SUB D socket for the RS 232      connection.    - RJ11 socket or terminal block for the connection      of RS 485 / RS 422   - Automatic checking of RS 485 emission and      reception. No adjustments are required.    - Baud rate: 9.600, 19.200, 38.400, 57.600 or     115.200   - Semi duplex (RS 485) and duplex compl (RS      422)   - Selectable DTE & DCE 
 | 
        View or print user's manual of the ICM5 signal/protocol converter     
 | 
| Technical specifications | 
| RS 232 protocol | 
 RXD:  max. +/- 30 VDC /  logic 1: 0.8 VDC,            logic 0: 2.4 VDC  TXD:  logic 1: - 8 VDC (typical),           logic 0: + 8 VDC (typical) 
 | 
| RS 485 protocol | 
  Output differential voltage:  max. +/- 5 VDC (no load)  Input differential voltage:  max. +/- 5 VDC  logic 1: - 0,2 VDC, logic 0: + 0,2 VDC  Up to 32 participants in parallel RS 485  Shut-off time: after one signal depending of the Baud rate 
 | 
| Maximum cable length | 
RS 232: 15 m / RS 485: 1200 m | 
| Baud rate | 
min. 9600 Baud, max. 115.200 Baud | 
| Power supply | 
9 ... 26 VDC, max. 125 mA, 85 mA | 
| Environmental conditions | 
  operating temperature: 0 ... + 50 °C  storage temperature:  - 40 ... + 75 °C /                              85 % relative humidity 
 | 
| Insulation | 
 RS 232 / RS 485 / power supply up to 1,000 VDC among them (3 channels) 
 | 
| Electromagnetic tolerance | 
 - disturbing emissivity: EN50081-2  - disturbing resistance: EN50082-2 
 | 
| Connections | 
 RS 485 / RS 422 (screw clips and RJ11), RS 232 through the 9-terminal SUB D switch 
 | 
| Case | 
plastic case | 
| Dimensions | 
25 x 85 x 89 mm | 
| 
  Delivery contents    1 ICM5 signal converter (RS 232 a RS 422 / 485) and user's manual 
 | 
  | 
   | 
| 
 Here you will find all the measuring instruments available at PCE Instruments. 
 | 
  | 
      Contact:  PCE Instruments UK Limited 
    Unit 11 Southpoint Business Park 
    Ensign Way, Southampton 
    United Kingdom, SO31 4RF 
    Phone: +44(0) 23 809 870 30 
    Fax: +44(0) 23 809 870 39 
   | 
  
      Contact:  PCE Americas Inc. 
    1201 Jupiter Park Drive, Suite 8 
    Jupiter 33458 FL 
    USA 
    Phone: +1-410-387-7703 
    Fax: +1-410-387-7714 
   |