Measures

Distribución de todo tipo de básculas en toda Europa: de PCE Group
UK office: +44 (0) 191 3773398 Fax: +44 (0) 191 3773357

Home
Business Terms
Faq's
Contact
 


Business
Terms


Contact

Calibra-
tion
service


Refe-
rences


Measuring
instruments


Scales and
Balances


Laboratory scale topseller

laboratory scale: PCE-999
Noise meters

laboratory scale
Radiation
detectors


laboratory scale: PCE-LD 1
Gas
detectors


laboratory scale: PCE-OC 1
Oscilloscopes

laboratory scale:: PCE-T395
Thermometers

laboratory scale:PCE-313A
Humidity
indicators


laboratory scale:PCE-DC 3.
Clamp
meters

laboratory scale:PCE-228
pH-Meters

laboratory scale:PCE-S 41
Stethoscopes

laboratory scale:PCE-DM 12
Isolation
meter


laboratory scale:PCE-830
Power and
harmonics analyser


laboratory scale:PCE-AM 81
Earth meters

laboratory scale:PCE-AM 81
Anemometers

laboratory scale:PCE-TC 3
Thermal
cameras


laboratory scale:PCE-889
Infrared
thermometers


laboratory scale:PCE-PH 22
Conductivity
meters


laboratory scale:PCE-VE 110
Videoscopes

laboratory scale:PCE-CT 28
Coating
thickness
meters


laboratory scale:PCE-G 28
Radiation
analysers


laboratory scale:PCE-G 28
Weather
stations


laboratory scale:PCE-G 28
Microscopes
USB


laboratory scale:PCE-G 28
Microscopes
 


Bordelaboratory scale:PCE-BS
Tabletop
scales

laboratory scale:PCE-CS HD
Crane
scales



Laboratory
Scales

laboratory scale:PCE-MB
Humidity content
Scales


laboratory scale:PCE-HS50
Hanging
Scales


laboratory scale:PCE-DS600
Kitchen
scales


laboratory scale:PCE-JS 300
Pocket
scales


laboratory scale:PCE-JS 300
Pallet truck
scales

laboratory scale:PCE-JS 300
Floor scales

PCE-ET 3000 series electric earth resistance meter
Earth and ground resistance meter (resistance / voltage) 
for houses and buildings 

Earth resistance meter is used to measure lightning-arresters or ground connection lightning-arresters for all kind of buildings. Earth resistance meter possesses a hermetic case and fulfils all the VDE 0413 safety requirements for the technical service operators. Earth resistance meter is appropriate for measuring ground electrodes, lightning-arresters or little earth resistance systems as well as for measuring power resistance, conductive elements and coupling components.
Modern switching circuits reduce the influences of  both pressure and earth resistance of the surrounding earth electrodes. Calibration of the earth resistance meter with the adjoining control mechanism avoids the loss of precision at measuring.
Frequency control of 850 Hz avoids the influence of scattered currents of the net and its harmonic elements. Besides, this meter has a filter incorporated to delete distorted signs. Earth resistance meter is delivered with the factory calibration however it can also have ISO calibration certificate.
You will find an overview of all the earth resistance meter at the following link.

Characteristics:

- 3 ˝ positions LCD display (máx. 1999)

- High accuracy

- Battery indicator / of range superation


- Data Hold


- Safety: IEC-1010-1 y CAT III 300 V

- Very good quality


- Components: checking cables: 15 m of red
  cable, 10 m of yellow cable, 5 m of green
  cable, ground needles, batteries and user
  manual.

- Optional ISO calibration certificate.

PCE-ET 3000 series digital earth resistance meter
See / Print user manual of the  PCE-ET 3000 series.
See / Print user manual of the PCE-ET 3000 electric earth resistance meter.

Connection slots of the earth resistance meter.

Removing the yellow protection case of the earth resistance meter (removing the case back) you will see the connection unit to connect the different cables: "E" for the black cable, "P" for the green cable and "C" for the red one with the needles of ground.
The connection collocation (depending on the kind of measurement (earth resistance or earth tension measurement) is indicated in the user manual (upper image) 

Measuring earth resistance.

Earth resistance meter is connected with the special ground components introduced on the earth by means of the checking cables. To make accurate measurements with this meter, ground has to be wet, if not ground will be wet. Ground components will be put in a straight line (place the black cable, then the green cable, the yellow one for one ground rod and finally the red cable for the second ground rod). Now everything is ready to connect the earth resistance meter to check the earth connection of your building. This can be also used inside a building to check that water connections with earth work properly. This meter has been developed according to IEC 1010-1 standard and fulfils all the  safety conditions for  control electronic mechanism (CAT III). Bellow, you will see some examples of earth resistance measurements (lightning-arresters) at the main door of PCE Group office in Freienohl. 

Earth resistance meter measuring earth resistance in a building.
At measuring earth resistance cables will be disposed according to specific distances you will see in the user manual. 
Usage of earth resistance meter.
When cables are placed correctly, customer will be able to switch on the meter which can placed on the ground.
Earth resistance meter with three checking cables.
Rods have to be placed at an appropriate distance to avoid checking cables are crossed or very closed each other.
Earth resistance meter with checking earth resistance cables.
Ground rods (with green and red cable) are introduce when grass is wet. Cables can be also adapted to tubles.

Technical specifications

Functions

Range

Resolution

Accuracy

Earth resistance

0 ... 19,99/ 0 ... 199/
y 0 ... 1999 Ω

10/ 100 mΩ / 1 Ω

± 2% + 2 positions

 AC Stress

0 ... 200 V AC
50/60 Hz

0,1 V

± 3% + 2 positions

lower measurement limit. 0,01 Ω
Current of measurement 2 mAeff / rms
Response time aprox. 2,5 s
Measuring quota 0,4 s
Frequency 820 Hz
Overload range in case of overlaoad, „1“ is shown
Power 8 x 1,5 V batteries
Dimensions 250 x 190 x 120 mm

Weight

1,5 kg 

Safety IEC- 1010- 1; EN 61010- 1
instalation category: III
EMV EN 50081- 1; EN 50082- 1
corresp. DIN/ VDE 0413 part 7
Delivering content
1 PCE-ET 3000 series earth resistance meter, chechin cables (15 m of red cable, 10 m of yellow cable, 5 m of green cable), 1 set of earth rods and the user manual
Optional
- Laboratory calibration and ISO calibration certificate (when ordered or with the annual re-calibrationa)
Technical specifications of the PCE-ET 3000 series earth resistance meter. Back to the main page

Here you will find an overview of all the measuring instruments available at PCE Group.

Contact:
Companies House England
Tursdale Business Park
Co. Durham - DH6 5PG
United Kingdom
Phone. +44 ( 0 ) 191 377 3398

Fax +44 ( 0 ) 191 377 3357

This page in German the PCE-ET 3000 series earth resistance meter quality meter in German in Italian the PCE-ET 3000 series earth resistance meter in Italian in Spanish the PCE-ET 3000 series earth resistance meter in Spanish. in Croatian the PCE-ET 3000 series earth resistance meter in Croatian. in French the PCE-ET 3000 series earth resistance meter in French. .


Below you will find an overview of the different product groups of measuring instruments

 Absolute Humidity Meters
 Accelerometers
 
Alert Meters
 Air velocity meters
 Analyzers (Colour)
 Analyzers (Gas)
 Analyzers (Lan)
 Analyzers (Noise)
 Analyzers (Oxygen)
 Analyzers (Ozono)

 Anemometers
 Barometers
 Borescopes

 Cable detectors
 (electrical)
 Calibrators
 Cameras (Infrared  
 Thermal Ima.)
 Capacitance Meters
 Coating Thickness
 Meters

 Chlorine Meters
 Clamp Meters
 Climate Meters
 Colour Meters

 Conductivity Meters
 Contact Thermometers
 Current detectors

 Data Loggers
 Differential Pressure   
 Meters
 Digital Multimeters
 Densimeters
 Detectors (Humidity)
 Detectors (Radiation)

 
Detectors (Voltage)
 
Dose Meters (Noise)

 Earth meters
 Endoscopes
 Environmental Meters
 Fiberscopes
 Flow Meters Air
 Flow Meters Gas
 Force Gauges (digital)
 Frequency Meters
 Gas detectors
 Geiger Counter
 Handheld Tachometers
 Hardness Meters
 Humidity Testers
 (Building material)
 
Hygrometers

Indicator Sound Level
Indicators (Humidity)
Instruments (Environmental)

Impedance bridges
Infrared Thermometers
Isolation Meters

Lan Network Testers
Laser Distance Meters
Laser level
Laser meters
Laser thermometers
LCR Meters
Length Meters
Light Meters
Lux Meters

 Manometers
 Mat. Thickness Meters
 Measurement Devices

Measu Meters Distance.
Measuring Wheels
Meters (Air, Distance, Power,
Pressure Radiation, Temperatur. Gas, Gloss)
Micrometers
Modular signal Converters
Moisture Indicator
Multimeters
Multi-Parameter Photometers

Noise Meters

 Odometers
 Ohm Meters
 Oscilloscopes
 Oxygen Meters
 Ozono Meters

Paper Moisture Meters
Penetrometers
pH-Meters
Pitot tube air flow
Pocket pH-meters
Power Analyzers
Pressure Gauges,
Pyrometers

 Quality Meters (Air)
 Radiation Counters
 Radioactivity meters
 Reader (Temperature)
 
Recoders Data
 Redox Meters
Refractometers

Relative Humidity
Rotation meters
Roughness tester

Salt Meters
Sensor (Temperature)
Signal Level Analyzers
Single-parameter Photometers
Sound Level Meters
Systems for Environ.
Stethoscopes (elect.)
Stroboscopes
Surface Thickness Meters

Tachometers
Telescope Meters
Thermo-anemometers
Thermo-Hygrometers
Temperature Probes
Testers (Conductivity, Earth, Electric, Insula.,  Noise,
pH, Resistance, Sound, Temp.)
Thermal stress
Thermal Imaging Cameras
Thermometers
Thermocouples
Thickness Meters
Turdibity Meters

Ultrasonic Flow Meters

VDE tester
Vibration Meters
Video endoscopes
Voltage meters