DM-9960 Multimeter
for all
kind of magnitudes, big display with bar
graph, very fast Peak measurements > 1 ms,
frequency up to 40 MHz, CATIII 1000V
standard
|
|
The DM-9960 multimeter has both manual
and automatic range selection as well as
a dual indicator with a numerical value
up to 3999 and a analogue bar graph with
40 segments where the measurement values
can be easily read and changes can be
quickly detected. This multimeter has a
range up to a maximum of 40 MHz and can
offer you innovative possibilities for
conventional measurements, for Peak
measurements of impulse input of
>1ms as well as for highly
accurate frequency measurements up to 40
MHz. The DM-9960 multimeter comes with a
complete input protection and it meets
the CAT III 1000 V standard. The
different functions are selected easily
by pressing the corresponding keys. The
multimeter has an automatic range
selection for DC voltage, AC voltage, DC
current, AC current, Ohms, measurement
of diodes, transit, capacitance,
frequency and temperature. Another
multimeter model with graphics,
interface and software (multimeter,
oscilloscope, logical analyser, ...) can
be seen
here.
|
|
-
Analogue graph bar with 40 segments
- Battery
indicator
- Measurement value, minimum /
maximum value and maintenance of the
peak value
- Measurement
of the relative value
- Diode test
- Transit test
-
Automatic range selection
- Automatic shut-off
- Security: IEC-1010-1; CAT III 1000 V |

DM-9960
Multimeter
View / print user's manual
 |
|
Technical
specifications |
| Function |
Measurement
range / Accuracy /
Resolution |
|
DC Voltage |
400
mV / ± 0,5 % + 2 dgt. / 100 μV
4
V / ± 0,8 % + 1
dgt. / 1 mV
40 V / ±
0,8 % + 1 dgt. / 10
mV
400 V / ±
0,8 % + 1 dgt. / 100 mV
1000 V / ± 0,8 % + 1 dgt. / 1
V |
|
AC Voltage |
400
mV / ± 1,0 % + 2 dgt. / 100 μV
4
V / ± 1,0 % + 2
dgt. / 1 mV
40 V / ±
1,0 % + 2 dgt. / 10
mV
400 V / ±
1,0 % + 2 dgt. / 100 mV
1000 V / ± 1,0 % + 2 dgt. / 1
V |
|
DC
/ AC Current |
0,4 mA / ± 1,0 % + 2 dgt. / 0,0001 mA
4 mA / ±
1,5 % + 2 dgt.
/ 0,001 mA
40 mA / ± 1,0 % + 2 dgt. / 0,01 mA
400 mA / ± 1,5 % + 2 dgt. / 0,1 mA
10
A / ± 1,5 % + 2 dgt. / 10 mA |
|
Resistance |
400
Ω / ± 1,0 % + 2 dgt. / 0,1 Ω
4 kΩ
/ ± 1,5 % + 2 dgt. / 1 Ω
40 kΩ /
± 1,5 % + 2 dgt. / 10 Ω
400 kΩ
/ ± 1,5 % + 2 dgt. / 100 Ω
4 MΩ
/ ± 1,5 % + 2 dgt. / 1 kΩ
40 MΩ / ± 3,0 %
+ 5 dgt. / 10 kΩ |
|
Capacitance |
4 nF / ± 3,0 % + 1 dgt. / 1 pF
40 nF / ± 3,0 % + 1 dgt. / 10 pF
400 nF / ± 3,0 % + 1 dgt. / 0,1 nF
4 μF / ± 3,0 % + 1 dgt. / 1 nF
40 μF / ± 3,0 % + 1 dgt. / 10 nF
400
μF / ± 3,0 % + 1 dgt. / 0,1 μF
4 mF / ± 3,0 % + 1 dgt. / 1 μF
40 mF / ± 3,0 % + 1 dgt. / 10 μF |
| Frequency |
4
kHz / ± 0,5 % + 2 dgt. / 1 Hz
40 kHz / ± 0,5 % + 2 dgt. / 10 Hz
400 kHz / ± 0,5 % + 2 dgt. / 0,1 kHz
4 MHz / ± 0,5 % + 2 dgt. / 1 kHz
40 MHz / ± 0,5 % + 2 dgt. / 0,01 MHz |
| Temperature |
-20 °C ...
+750 °C / ±1 % + 2°C / 1°C |
|
Indicator |
20mm
LCD display with bar graph |
|
RS-232 interface |
yes |
|
Power |
2
x 1,5 V micro batteries |
| Dimensions |
88
x 185 x 40 mm |
|
Weight |
350
g |
|
Delivery
contents
1 DM-9960 multimeter,
testing cables,
2 micro
batteries
and user's manual. |
|
Optional accessories
- ISO
calibration certificate
for companies that wish
to include this device in
their set of internal
testing tools or for annual
recalibrations. The ISO
certificate includes a
laboratory calibration and a
control document with all
the measurement values.
The ISO calibration
certificate can be done in
voltage (AC / DC) or in
current (AC / DC).
|
 |
|
-
Amp clamp adaptor
Adaptor for indirect
measurement of current up to
1000A without interrupting the
cable.
- Range: 200 / 1000A DC / AC
- Accuracy: ±1.5 / 2%
- A DC zero reset
Dimensions: 190 x 64 x 33mm
Maximum diameter of cable:
33.5mm |
 |
|
-
Revolution adaptor
Adaptor with revolutions
sensor and 1m cable.
For optical measurement
of revolution between 100
and 20,000 RPM in two
ranges.
- 0.1mV DC / 1 RPM
(range 1)
- 0.1mV DC / 10 RPM
(range 2)
- Dimensions: 190 x 73 x
37mm |
 |
|
-
Pressure adaptor
Adaptor with pressure
sensor and 1m cable.
For absolute measurement
of pressure between 3.5 and
3500kPa.
- Accuracy: ±1% (up to
1700 kPa); ±2% (up to
2400 kPa) and ±5% (up to 3500 kPa)
- Resolution: 0.1/ 1 kPa
- Dimensions: 100 x 50 x
25mm; 1/4" sensor. |
 |
|
-
Humidity adaptor
Adaptor with humidity
sensor in a handle and with
1m cable.
- Range: 10 to 95% r.h.
- Accuracy: ±3% r.h.
- Resolution: 0.1% r.h.
- Dimensions: 100 x 50 x
25mm |
 |
|
-
Light adaptor
Adaptor with light sensor
and 1m cable.
- Three rages: 0 to 2000
/ 0 to 20,000 and 0 to
50,000 lux
- Accuracy: ±5%
- Resolution: 1, 10, 100
lux
- Dimensions: 100 x 50 x
25mm |
 |
|
-
Air velocity adaptor
Adaptor with an air
velocity sensor and 1m
cable.
- Range: 0.2 to 30 m/s;
- Accuracy: ±2%
- Resolution: 0.1 (m/s;
km/h; knots)
- Dimensions: 100 x 50 x
25mm. |
 |
|
-
Sound adaptor
Adaptor with sound sensor
and 1m cable. A-weighting; can be
externally calibrated (PCE-SC
41 calibrator)
- Ranges: 30 to 130dB (in
three ranges)
- Accuracy: ±1.5dB (IEC
651 class II)
- Dimensions: 107 x 53 x
29mm |
 |
|
-
EMF adaptor
Adaptor with EMF sensor
and 1m cable.
- Range: 0 to 20 microTesla
/ 200 milliGauss
- Accuracy: ±4%
- Resolution: 0.1 µTesla /
1 milliGauss
- Bandwidth: 30 to 300 Hz
- Dimensions: 100 x 50 x
25mm |
 |
 |
 |
|
Here you will find an overview of all the measuring instruments available at PCE Group. |
Contact:
Companies House England
Tursdale Business Park
Co. Durham - DH6 5PG
United Kingdom
Phone. +44 ( 0 ) 191 377 3398
Fax +44 ( 0 ) 191 377 3357 |
|
This page in German
in Italian
in Spanish
in Croatian
in French
. |