PCE-318 noise meter
noise meter with a range between 26
and 130dB (A)
and an analogue output
/ can be recalibrated /
class II (accuracy ±1.5dB)
|
|
The PCE-318
noise meter determines the volume from an
acoustic level of 26dB(A).
For this, the PCE-318 noise meter is perfect for
determining noise minimums, such as those emitted by computer
fans. The class II noise meter with large display is adequate
for taking measurments in different environments, such as the
work place, in the control of machines, etc.
This device has been developed according to
IEC 651 type II and
has an accuracy of ±1.5dB. Another
advantage of this noise meter is its analogue output that allows
it to be connected to an external data logger to take readings
over a duration of time.
Here
you will find other noise meters with similar
technical specifications but with internal memeory and software.
|
|
-
Measurement range of
26 to 130 dB
- 6 ranges to
choose from - Analogue output
(AC & DC) / to be used in
combination with an
optional data logger (see
optional accessories below) -
Memory for 99 readings
that can be shown on
the dsiplay. -
Frequency range 31.5 Hz to 8 kHz -
Large display -
Adjustable measurement ranges: Low &
High - Frequency weighting:
A and C (Information)
- Temporary value: Slow & Fast (Information
about temporary value) -
Min. &
Max. Hold function -
Can be mounted on a tripod -
Includes
microphone windscreen
View or print the user's manual
|
 |
|
Technical specifications |
|
Measurement range |
26 to 130dB in 6 ranges:
26 to 80dB / 30 to 90dB / 40 to 100dB 50 to 110dB / 60 to 120dB
/ 70 to 130dB |
|
Resolution |
0.1dB |
|
Accuracy |
±1.5 dB ref. 94 dB to
1kHz |
|
Frequency range |
31.5 Hz to 8 kHz |
| Temporary
value |
FAST & SLOW |
| Frequency
weighting |
A and
C |
|
Memory |
99 readings
shown on display |
| Output |
analogue, AC &
DC |
|
Operating conditions |
-10 to +50°C, less than 90% r.h. |
| Storage
conditions |
-10 to +60°C,
less than 75%
r.h. |
|
Power |
9V battery (PP3) |
| Weight |
approx.
260 g |
|
Dimensions |
264 x 68 x 27 mm |
|
Standard |
IEC 651 type II (class
II) |
|
Contents |
|
PCE-318 noise meter, microphone
windscreen, calibration screw, 9V battery,
3.5 mm jack for analogue output,
carrying case and user's manual |
|
Optional accessories |
|
Acoustic calibrator
Acoustic calibrator for regular recalibration. The noise meter
comes calibrated but the sensor suffers oscillation over time and
with the acoustic calibrator can be recalibrated independantly
to allow for optimum measurements. |
 |
|
ISO calibration
certificate
For companies that wish to include te
device in thier group of internal tools or for annual recalibrations (in
cases when the calibrator is not used).
The ISO calibration includes a laboratory calibration
includes a document with all the measurement values. |
 |
|
Data logger
The device can be attached to this data logger to
take readings over a large duration of time. The data logger has
4 inputs and a memory capacity for 32,520 readings. If you
connect four devices to the data logger at the same time,
approximately 8000 readings will be avaiable for each channel.
To be able to use the data logger, you must acquire the
necessary software pack and cables. |
 |
|
Software
pack for the data logger Windows software
and RS-232 cable for use with the data
logger. The software allows you to: -
to adjust the data logger's settings -
to read the stored data -
graphic representation of readings on a PC |
 |
|
RS-232 to USB
adaptor
The software pack comes with a standard RS-232
data cable. If you wish to send the data online or transfer later
the data saved in memory to a laptop or another portable data device,
you will need this USB adaptor. |
 |
|
Power cable 180 cm
long open ended cable to connect directly to the data logger, or
DC inputs of 0 to 2.5 volts at
one end and a jack connector at the other end. (the
jack connector is included as part of the noise meter shipment). |
 |
|
Power adaptor
The supply of regular power will prevent
erroneous measurements caused by failing batteries. If you are
going to take measurements for long periods of time with the data
logger connected, it is recommended you use a power adaptor. |
 |
|
Tripod
Light-weight aluminium tripod. It's
useful for making a series of measurements and guarantees that
readings can be reproduced more accurately by keeping the microphone
fixed in place.
Furthermore, the user can be free to manually
record readings or to perform other tasks. |
 |
|
Microphone extension cable
5 meter long cable. If the noise meter is used
with this component, it will be able to measure directly the
source of sound in machines or to check
products.
It will also allow for readings to be taken in
areas that are difficult to access. |
 |
 |
 |
|
Here you will find an overview of all the
measuring instruments available at PCE Group.
|
If you have any doubt, call our
technicians on:
Germany:
+49 (0)29 03 976 99-52
Italy:
+39 0583 975 114
Spain:
+34 967
543 548
|
This page in German
in Italian
in Spanish
in Croatian
in French
. |