Cup vane anemometer
PCE-A420
digital cup vane anemometer, wind
direction will not influence the measurement
|
|
Without a doubt, the main advantage of this
handheld cup vane anemometer is that it doesn't
need to be held exactly in the direction of the
wind. Anemometer with impellers typically have to
be held exactly in the direction of the air flow
to take accurate measurements. However, this
cup vane anemometer's system is so sensitive
that it responds
to the smallest of air currents.
At this
link you can find other anemometer with
memory and an interface for connectivity to a
computer and software to allow for data
transfer. This
link has similar anemometers but with a
measurement range of up to 45m/s.
|
|
 |
|
- Data logger for 100 readings
- Very sensitive cup vane system
- Wind direction is of no importance
- Variety of units to choose from: m/s, km/h,
ft/min, knots or miles/h
- Ingress protection IP 65 |
- MIN, MAX and HOLD functions
- Auto shut-off (auto disconnect)
- Anemometer with large LCD
PCE-A420 anemometer
View or print the user's
manual
|
|
Technical specifications |
|
Measurement range |
0.9
to 35.0 m/s
2.5 to 126.0 km/h
1.4 to 68.0 knots
1.6 to 78.2 miles/h
144 to 6895
ft/min |
|
Resolution
|
0.1
m/s
0.1 km/h
0.1
nudes
0.1 mph
1 ft/min |
|
Accuracy |
±2% |
|
Cup vane diameter |
70mm |
|
Display |
28
x 19mm LCD |
|
Enclosure |
plastic |
|
Power |
4
AAA batteries (1.5V) |
|
Cups |
plastic with 135mm diameter |
|
Dimensions |
190
x 40 x 32mm |
|
Weight |
180g |
|
Operating temperature |
0
to 50°C |
|
Operating humidity |
<80%
r.h. |
|
Photo of the PCE-A420
anemometer in use |
|

To perform a correct
measurement with the PCE-A420 cup vane anemometer:
First turn the meter on, then hold the meter
vertically so the cups can rotate until the wind
velocity is displayed. In the following picture you
can see how to measure wind speed with the PCE-A420
cup vane anemometer.
As previously stated, different measurement units can be
selected
with the PCE-A420 cup
vane anemometer: m/s, km/h, knots, ft/min and mph. To
change measurement units in the PCE-A420 cup vane
anemometer, you must press the key Data Hold until
the desired unit is displayed, then depress the key.
You can save the unit in the memory of the PCE-A420
cup vane anemometer to be displayed every time the
meter is turned on. If the messages Hold or
REC appears in the display, you cannot change the
measurement units. Moreover, you could fix a value in
the PCE-A420 cup vane anemometer by pressing the
Hold key during the measurement. To deactivate this
function please press the Hold key again. |
|
Contents
PCE-A420 cup vane anemometer, batteries,
case and user's manual. |
|
Optional accessories
- ISO calibration certificate for the PCE-A420 cup
vane anemometer. |
|
ISO calibration and certification
An ISO calibration certificate can be
acquired for this anemometer. A certificate of control with
the details of your company is issued
in a laboratory certification and
calibration for the ohmmeter, so you can register the devices in their
intra-corporate consortia ISO control instruments. This document also
certifies that such devices may be adjusted again according to
national standards. Below, you will find more information on calibration:
Calibration: control of the accuracy
in the measurement magnitudes of the anemometer without the intervention
of the measurement system. Calibration also refers to the determination
of the systematic deviation of the anemometer display in relation to the
real value of the measured magnitude.
Calibration document or certificate:
document with the technical properties of the anemometer according to the
national organization of measurement.
Calibration interval: to perform
correct measurements, the anemometer must be calibrated at regular
intervals. This period of time is called calibration interval. It's
difficult to determine this period with accuracy but you should consider
the following factors:
•
Performance of the measuring instruments
• Frequency of use
• Operating conditions
• Previous calibration stability
• Measuring accuracy required
• Determining factors of the quality control systems used by companies
This means that the user is responsible for checking and controlling the
interval between calibrations. We recommend that this calibration
interval should be somewhere between 1 and 3 years. We also offer the user our
expert advice to solve any questionss related to the process of establishing
calibration intervals or any other technical questions.
Take into consideration:
The accuracy of the calibration depends on the anemometer and the sensor
combined. In the case of the anemometer PCE-A420, this means that the
calibration should be done for up to four temperature sensors. |
 |
 |
|
Here you will find an overview of all the measuring instruments
available at PCE Instruments. |
|
Contact:
PCE Instruments UK Limited
Units 12/13 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone. +44 ( 0 ) 2380 98703 0
Fax +44 ( 0 ) 2380 98703 0 |
|
This
page in German
in Italian
in Spanish
in Croatian
in French
 |