pH meters At PCE Instruments you will find pH meters for use in laboratories, aquariums, or in the industrial sector to measure pH value. Our pH meters from Hanna Instruments provide a complete range of devices. These handheld pH meters bring together almost all the characteristics available in the "best" handheld devices. These pH meters represent the best solution for quick and portable results for measuring pH values. One of these pH meters , the Combo, also measures conductibility and temperature. Our pH meters can be calibrated, come with pH electrodes and with ISO certification. If you can't find the pH meters you are looking for, please contact us and we will help you find the best solution to suit your needs by calling our offices on: +44 (0)2380 987030 and our technical staff will advise you regarding our products. Our engineers and technicians will be happy to help you with the pH meters, and of course, with the other products in the field of regulation and control, and scales and balances. Technical specifications for pH meters can be found at the following links:
|
|
- PCE-PH 22 series pH meters (combined pH meters for pH and temperature)
|
 |
- PCE-228 series pH meters  (handheld pH meters for pH value, Redox and temperature with RS-232 interface) |
 |
|
- HI-9124 series pH meters (water and dust resistant pH meters, multifunctional, pH and temperature sensor included, max 120 ºC)
|
 |
- PCE-PHD1 series pH meters  (pH-testers multifunction for pH values, conductivity, oxygen and temperature) |
 |
|
- PCE-PHD2 series pH meters (pH meters Redox value and temperature (max. +100 ºC) with internal memory for 64)
|
 |
|
- HI 9828xx series pH meters (13 parameters, multiparameter intelligent probe, easy data management, also availble with GPS)
|

|
|
- PHT 810 series pH meters (pH meters with current value memory / possibility of connecting to several electrodes / wide application)
|

|
|
- PCE-PH20S series pH meters (pH meters for trasmitting pH values for earth and ground)
|

|
|
- HI 99131 series pH meters (pH meters for galvanising processes and temperature sensor integrated, max. 60,00 °C)
|

|
|
- PCE-228 M series pH meters (handheld pH meters for pH value, Redox and temperature with RS-232 interface)
|
 |
|
- CPC-401M series pH meters (pH meters to measure pH in the food sector, RS-232, Memory 200 values)
|
 |
|
- PCE-BPH1 series pH meters (nech testers with ATC, parameter setting between pH and mV, max., min. and HOLD functions)
|

|
|
- PH 209 series pH meters (pH bench testers of pH, conductibility and temperature)
|

|
|
- PH 213 series pH meters (bench and laboratory testers for pH /mV /°C with RS-232 interface and software)
|

|
|
- pH meters for stationary use (pH meters for the connection to evaluation units, standard output signal)
|

|
|
Please note the following recommendations for using pH meters: You must recalibrate after continued use or after a long period of downtime. The natural deviation of electrodes PH should be corrected. Most pH meters have an internal calibration function, so it is not necessary to perform this calibration by screws. In any case, you will require some of calibration options we offer (most in bags as calibration kit) and are adapted the corresponding meter.
Below you will find a selection of the different uses that you can request for pH meters:
|

|
 |
 |
|
pH meters to measure pH value and current temperature.
|
pH meters measuring pH inside of a aquarium. |
pH meters designed for reliable measurements in laboratories |
Overview about ph-testers: pH meters are measuring instruments which indicate the pH value o f an aqueous solution. The value is obtained electrochemically and not on the basis of the acid indicators (tapes). The most widely used operating principle uses the potential of a glass electrode. A reaction in the glass membrane generates an electrochemical potential that is in direct dependence with concentration H ions. The difference of potential to reference electrodes creates a voltage shows linearly pH value. In most cases you can use a silver chloride cell as reference electrode, which is lined with a glass electrode, forming a measurement circuit. The reference electrode is connected to the solution through a diaphragm, which is usually composed by a glass, ceramic or platinum sponge. Most of the electrodes of pH meters must be kept, at least, a glass with tap water, but it is better in a saline solution.
|
|
|
If you wish to view or print a selection of pH meters from our catalogue, click the PDF symbol. 
|